For your information

You are being redirected to one of our divisional subsites which contains more detailed information on the required division. To navigate back to the main Invicta Group site, please click the link found in the footer at the bottom of the page.

Example Template 1

Quick Quote

Contact Fraser Shearer Sarun Vysakham Ben Tan Azim Rizvi Anand Raghavan Our USA Office

To get a quotation or arrange a free site survey - Call Fraser Shearer Sarun Vysakham Ben Tan Azim Rizvi Anand Raghavan Our USA Office on

Or Send us a message

Quick Quote

Contact Fraser Shearer Sarun Vysakham Ben Tan Azim Rizvi Anand Raghavan Our USA Office

Fire Barriers

During a major fire large compartment, walls or enclosures may be subjected to extreme conditions and impact damage due to falling debris. This often leads to failure and, in some cases, total collapse. In circumstances of extreme fire, it is vital both materials and construction are capable of sustaining their design function.

When subjected to these extreme conditions, Invicta’s Durasteel systems achieve a fire rating of 240 minutes and, together with their ability to withstand impact, provide the strength to protect in the harshest of fires.

FIRE BARRIER CONSTRUCTION

Durasteel partitions provide vertical fire barriers to meet the requirements of BS 476: Part 22: 1987.
The partition and barrier systems combine superior levels of fire resistance and high surface impact resistance.

They will withstand the wear and tear of industrial and commercial environments and resist the forces of high pressure hose streams encountered during fire-fighting.

These outstanding characteristics provide a durable and fire safe method for the construction of vertical barrier systems to maintain compartmentation in industrial environments.

When designing the Durasteel framing system, consideration must be made for expansion, deflection, wind loading and load bearing requirements.

The constructions have been tested to both fire and impact resistance in accordance with BS 476: Part 22: 1987 and similar international standards with the construction subjected to impact of 3000Nm both prior and after the fire test.

FIRE BARRIER FEATURES

  • Four Hour Fire Resistant
  • Impact Resistant
  • Moisture Resistant
  • Lightweight – No foundations required
  • Space-Saving, with excellent Structural Strength and Integrity
  • Demountable / Remountable
  • Maintenance Free
  • Suitable for Internal and External Locations
  • Can be Prefabricated Offsite
  • Purpose Built to meet Individual Requirements
  • Vibration Resistance
Enquire Now

Key Features

4 Hour Fire Rated

Fire Attack In Both Directions

Impact Resistant

Moisture Resistant

Acoustic Sound Insulation

Climate Impervious

Fully Demountable & Relocatable

Low Maintenance

Proven Performance

Internationally Tested & Certified

Case Studies

Fire barriers & sliding doors protect London Luton Airport

Luton, UK View case study

Durasteel Fire Barrier Protects Multi-Million Pound Aircraft Hanger

UK View case study
barrier - freestanding

Fire barrier stops major fire at brewery bottling plant

Runcorn, UK View case study

What our clients say...

Global Infrastructure

"We just found Invicta very easy to deal with at a management and site level"

Read the full testimonial

Structure Tone

"We have been massively impressed with the professionalism of Invicta from start to finish."

Read the full testimonial

ISG PLC

"Invicta have great personnel that are extremely knowledgeable that can advise and provide solutions to issued that arise on site."

Read the full testimonial

LDD Construction

"Due to commitment of the site team, works were completed on program - 10/10"

Read the full testimonial

Neary Construction

"Works completed to a high standard in a very tight programme."

Read the full testimonial

Costain Skanska JV

"Invicta mobilised resources to achieve our critical timeframe"

Read the full testimonial

AnelMep

"Invicta has proven to be a valuable business partner for AnelMep with its expertise, commitment and professionalism shown in the project."

Read the full testimonial

RLS-JV

"lnvicta Durasteel has proven to be a valuable partner for RLS-JV with its expertise, commitment and professionalism shown throughout the project and the works being delivered on time and to the highest standards."

Read the full testimonial

Betchtel Limited

"I am pleased that you took on the contract in the first instance and even more pleased with the Project Manager you put in charge of it – thank you Andy."

Read the full testimonial

Want to start a project with us?

Drop us a line and some details and we’ll get back to you as soon as possible.

    SpecUp - System Specification Wizard

    Answer the 5 short questions below to receive your recommended Durasteel system specifications. Hover over the ? icons for a brief explanation.

    Question 1/5

    Type of system required?

    Question 2/5

    Fire rating required?

    Question 3/5

    Fire integrity-only or integrity and insulation?

    Question 4/5

    Fire attack risk from one side or both sides of the system?

    Question 5/5

    Blast rating required in addition to fire rating?

    Creating your results page

    Thanks for completing the SpecUp, you’ll be redirected to your results shortly.

    Click here if you aren't redirected after a few seconds

    Start your project

    Tell us about your project. Please complete this form. One of our sales team will come back to you with more details. If you prefer, you can drop us an email.





      Project details




      Attach any files that may assist us with your enquiry (specs, drawings, bill of quantities, etc.)

      Acceptable file types are .pdf, .jpg, .dwg, .xls, .xlsx, .doc, .docx, .zip and .rar up to a maximum of 15mb. For files larger than this, please use the external file upload link below.