For your information

You are being redirected to one of our divisional subsites which contains more detailed information on the required division. To navigate back to the main Invicta Group site, please click the link found in the footer at the bottom of the page.

Quick Quote

Contact Fraser Shearer Sarun Vysakham Ben Tan Azim Rizvi Anand Raghavan Our USA Office

To get a quotation or arrange a free site survey - Call Fraser Shearer Sarun Vysakham Ben Tan Azim Rizvi Anand Raghavan Our USA Office on

Or Send us a message

Quick Quote

Contact Fraser Shearer Sarun Vysakham Ben Tan Azim Rizvi Anand Raghavan Our USA Office

Home Durasteel Interactive System Diagrams Insulated Durasteel Barrier

Insulated Durasteel Barrier


Arrow Icon

Hover over the points for details

Durasteel Panel

Single layer of 9.5mm thick Durasteel 4 hour composite panel fixed on one side of the channel with M5.5 steel self drill and tap Tek screws at 250mm nominal centres


M5.5 Tek Screw Fixings

Typically 38mm long 5.5mm self drill and tap Tek screws


Angle Cleat

Typically 60mm x 60mm x 3mm or 120mm x 60mm x 3mm x 60mm long, fastened to each channel member with two M10 x 25mm steel bolts, nuts and washers


Steel Framework

Typically 80mm x 60mm x 3mm or 150mm x 60mm x 3mm Cold Rolled Channel framework, with vertical channels set at a maximum 1200mm centres


Mineral Wool Insulation

Varies from 80mm to 150mm thick and 60kg/m³ to 140kg³ density depending on thermal insulation performance required


Insulated Durasteel Barrier

Fire Resistance: 240 minutes (integrity and insulation)

Durasteel insulated fire barriers are used in constructions where high insulation as well as stability is required during a fire, and are designed to prevent the passage of heat from a fully developed fire on the exposed face.

Our insulated fire barriers can be designed to provide anywhere from 60 minutes (1 hour) thermal insulation up to 240 minutes (4 hours), with a maximum permitted temperature rise allowable on the surface of the unexposed face of 140°C as a mean temperature over the entire surface, or a maximum temperature rise of 180°C at any single point on the surface.

Share/Like this page

Accreditations & Affiliations

SpecUp - System Specification Wizard

Answer the 5 short questions below to receive your recommended Durasteel system specifications. Hover over the ? icons for a brief explanation.

Question 1/5

Type of system required?

Question 2/5

Fire rating required?

Question 3/5

Fire integrity-only or integrity and insulation?

Question 4/5

Fire attack risk from one side or both sides of the system?

Question 5/5

Blast rating required in addition to fire rating?

Creating your results page

Thanks for completing the SpecUp, you’ll be redirected to your results shortly.

Click here if you aren't redirected after a few seconds

Start your project

Tell us about your project. Please complete this form. One of our sales team will come back to you with more details. If you prefer, you can drop us an email.





    Project details




    Attach any files that may assist us with your enquiry (specs, drawings, bill of quantities, etc.)

    Acceptable file types are .pdf, .jpg, .dwg, .xls, .xlsx, .doc, .docx, .zip and .rar up to a maximum of 15mb. For files larger than this, please use the external file upload link below.